The Falcon 8200 series operator has a circuit that shuts down the operator when a resistance of 15 lbs. occurs, so the operator will not be damaged.
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device.  Maximum allowed force to retract the Von D...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.
The "Fire Alarm" indication occurs when there is no connection across terminals 13 & 14. Check to verify that the "Fire Alarm" shunt (R1 jumper) on the I/O board has not been cut. Install jumpe...