adjustments for track door closer LCN

RELATED FAQS

Question
Answer
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm door closers...
LCN started putting on the green dials for the spring adjustment on the 4041's in 2001.
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments.  Monthly, quarterly, and annual visual inspections are recommended for Fire/...
The 330 closer and parts were discontinued in early 2009. LCN does not have any parts available for the 330 series closer. The LCN 3030 Series would be the comparable closer replacement to the...
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.