ALK wiring diagram

RELATED FAQS

Question
Answer
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThe Schlage electrified L-Series wiring diagram can be found here and the re...
Applies to L9080EL/EU. L9082EL/EU (Discontinued)The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below. 24VAC or 24VDC (maximum 26V, ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
Wiring and Riser diagrams can be accessed at:Common wiring diagrams can be accessed at:  http://kc.allegion.com/.   Click on the "Common Wiring Diagram" link.To request a custom wiri...
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...
 The 10-042 is an electric strike used for cylindrical and tubular latch sets.  VOLTAGE  24 VAC  12 VDC  AMPERAGE  0.74A 0.33A   FREQUENCY  60 HZ ...
As of June 2011 the electrified T locks can support 12 or 24 Volts.  You do not need to specify 12 or 24 when ordering since the solenoid is capable of either voltage out of the...
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...
The MA lock can be specified in a 12 or 24V DC configuration (default is 12V). Additionally, an AC power source may be used as long as a rectifier is installed in the circuit (not provided). He...
For additional details and a wiring diagram see the MA service manual page on electrical requirements here. 
All new 22, 33/35A and 98/99 series exit devices with exit alarm ALK option can be hard wired to the PS902 power supply as a standard  feature.
Update the PIB300-2D firmware to version 2.13.1 or higher to be compatible with Brivo Access Panels
Update the PIM-400-TD2 firmware to version 2.14.2 or higher to be compatible with Brivo Access Panels
The 8310-806K/R is used when a remote OFF/AUTO/HOLD OPEN is required and is normally used with a 4630/4640 CS (concealed switch) unit.
For wiring diagram see here.
The HSA is an electrically controlled closer/holder designed to provide easy passage for groups of pedestrians through high traffic doors. - In 2006, we changed the Scanner in all HSA units to a s...
The 4630/4630 operator has a 12 VDC and 24 VDC output that can power an electric strike or maglock. The wiring diagrams are shown on page 14 of the installation instructions (attached). 4600 Insta...
There are 2 wiring diagrams for sequencing a double door vestibule application shown on page 13 of the 4630/4640 installation instructions.
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The 8310-865 RF receiver connection to the Falcon 8200 operator are: RED and BLACK power wires on the receiver connect to the 12V AC terminals on the Falcon operator. The WHITE wire from the COM t...
See Point to Point wiring diagram here.
Chexit devices shipped after 8-24-2015 with motor driven:Attached is the installation instructions of the the Von Duprin Chexit devices that includes the wiring diagrams.Installation Instructions&n...
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...
The Falcon Exit Alarm option was updated in June 2012 to include the following benefits. Louder Alarm 95dbs vs 87dbs Easier battery changes 24Vdc hardwire(HW) option included w/ standard board...
The PS9 power supply was discontinued.  The new exit alarm ALK can either use a 9VDC battery or 24VDC regulated power supply. There is no direct replacement for Von Duprin PS9 power supply. Cur...
PCB only for the Alarm Kits prior to June 11th, 2012 is part #650335 and was used in the older 17 & 18 devices, 19, & pre June 2012 24/25's.
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.
Exit alarm ALK operates with 9VDC battery and doesn't required a power supply.If you choose to hard wire the exit alarm ALK use the PS902 power supply.Exit alarm ALK requires 24VDC regulated power ...
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...
 One PS902 power supply will run up to six Von Duprin exit alarm ALK devices. PS902  power supply must be set to 24VDC to operate the exit alarm ALK.  Exit alarm ALK exit devices must be as clo...
PS902
The current Von Duprin ALK comes standard with the External Inhibit feature.
If the green terminal block has been broken off of the exit alarm ALK you must replace the exit alarm ALK PC board part number 101030-00.
Partner Solution: Integrated Access Control Solution with AD-300 Hardwired, AD-400 Wireless Locks and Avigilon RedCloud Access Control System.See the download cut sheet at:Avigilon Red Cloud&n...
Reference The 914 Installation instructions.
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
The new exit alarm ALK uses the 24VDC regulated PS902 power supply.
The part number for Von Duprin exit alarm ALK board is 101030-00.
There are three main failures with an ALK.  Problems are usually caused by a bad power source(battery), bad RX/LX Switch or a bad circuit board.  Try installing a new battery and wai...
Yes.  The exit alarm ALK is shipped standard with a RX, request to exit switch, but can work with the optional LX, latch bolt monitor switch.  If there is no switch in the device it will never alarm.
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.
No, the exit alarm ALK printed circuit board has been always green.
The Exit Alarm takes a 1 1/8" Mortise cylinder with a straight cam. See first page of Exit Alarm inst below. Exit Alarm inst
The RX switch is required to activate the ALK. The RX switch monitors the pushbar and will signal the ALK to go into alarm when the pushbar is depressed. The RX switch also allows free in...
Current exit alarm ALK released in November 2010 does ship standard with an EI (external inhibit) option.  ALK shipped prior to this would only have EI if ordered as a Special option.
The sign for exit alarm, ALK, is SIGN-1.
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.
The ALK uses a 1 1/4" mortise cylinder with straight cam. (NO DOGGING)
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.
The standard exit alarm ALK devices are not available with dogging option. The device can be ordered through Engineering Special with dogging option on non fire exit devices. This special is o...
The Von Duprin exit alarm ALK draws about .25 amp. PS902 power supply powers up to 8 exit alarm ALK. PS904/914 powers up to 16 exit alarm ALK. PS906 powers up to 24 exit alarm ALK. 
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...
If the spring on the Von Duprin exit alarm ALK board is not located correctly as shown on the instructions, then the vibration from the horn allows the cylinder to turn and shut the exit alarm ALK ...
Depends on what is being ordered; SS can stand for either the "Signal Switch" or the "Silk Screen" push bar. The SS (Signal Switch) and ALK (Exit Alarm) sit in the same location in the exit devi...
AR1 is Auto-Reset 1.5 minute, AR3 is 3 minute, or AR6 is 6 minute option processed through engineering specials on a Von Duprin exit alarm ALK.
The Chexit device has a different base plate and center case than the ALK.  The Chexit device would need to be replaced with an ALK device.
The Von Duprin exit alarm ALK shipped after November 2010 are new style boards and can be identified by the 3 terminal blocks and LED.  Only these ALK will work with 24vdc power supply.
Exit alarm ALK devices are not recommended for exterior application. We do not offer water proof exit alarm ALK devices.
The Von Duprin exit alarm ALK only operates with 24VDC regulated power supply and is not available in 12VDC.
The new Von Duprin exit alarm ALK shipped after November 2010  has an LED indicator.
There is currently an Exit Alarm Kit for the 19 device. It is ordered by description: 19 EAK 3' x Finish 19 HWEAK 3' x Finish (Hardwired version) 19 EAK 4' x Finish 19 HWEAK 4'' x F...
A low battery could cause the exit alarm ALK to chirp.  Replace the battery and if it is  still chirping, then replace the circuit board part number 101030-00.