autoOPERATOR WITH VERTICAL ROD DEVICE

RELATED FAQS

Question
Answer
The 98/99 rim and vertical rod exit devices are shipped with NL drive screw to function as a Night Latch. To convert the device to Class Room, remove the NL Drive Screw on 98/99 center case ass...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: Remove ...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...
Devices built After 2/28/2011: Use a 1 1/8" - 1 1/4" mortise cylinder with straight narrow cam. (Cam profile same as the Schlage B520-731, see table below for part numbers) Devices built Befo...
 Modular 1-1/8"  Modular 1-1/4"  SFIC and FSIC  Non-Modular Non-IC Conventional  Non-Modular Non-IC Everest Primus  B520-730  B520-731  B520-2...