The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width. See the Schlage Minimum Stile Guidelines for the minimum stile for each...
Depending on the door construction the minimum stile may differ but a safe dimension would be 4-3/4". CUSTOMER must check door construction.
The pocket depth requirements of the case is 4 1/2".