CX, DE5101, RCM, DE (390DEL, DE5101, CX, RCM, 390+DEL, 101+, 101+ Series)
CX, DE5101, RCM (390DEL, 101+)
Only applicable for solenoid driven Chexit devices shipped from the factory prior to 8-24-2015; Chexit solenoid coil resistance between the green and orange wires is 110-140 ohm and betw...
Chexit devices shipped after 8-24-2015 with motor driven:Attached is the installation instructions of the the Von Duprin Chexit devices that includes the wiring diagrams.Installation Instructions&n...
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...
The following Legacy information is important to understand before cross referencing power supplies: PS-900 option boards will NOT install onto the legacy power supplies. This includes battery a...
Von Duprin PS914-4RL power supply replaces the PS873-4TD.
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summary Legacy Supply (PS873) PS902 &...
PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 board 900-2Q 2 zone control for QEL 2Q board 900-4R 4 relay control, no timin...
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q Yes Yes 900-4R Yes Yes 900-4RL Yes Yes 900-8F Yes Yes 900-8P Yes Yes 900-B...