Answer
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong h...
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer.  If required, handing can be verified by looking at ...
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...
When using the 4111 with a bar style coordinator MB-mounting brackets ordered from IVES are required. The brackets wrap around the coordinator to provide a surface for mounting the parallel arm ...
The 1370 series closer was discontinued on Oct. 4th, 2008The 1260 closer hole pattern is 9-1/16" x 3/4", which is NOT the same hole pattern as the 1370 closer. The 1260-18QF plate does have the s...
Allegion does provides professional support to Architects and Design Professionals. For information related to specification development and support, Website for Architects and Design Professiona...
Allegion provides professional access control support to Security Consultants and Security Integrators.  For information related to specification development and support,Access Contro...
Those holes are for mounting the coordinator mounting bracket itself.  The brackets must be drilled and tapped for the hardware you are mounting to them.