El not holding latch

RELATED FAQS

Question
Answer
(For best viewing, use Chrome or Firefox browser.)ALLEGION EL SOLENOID ELECTRIC LATCH RETRACTION TROUBLESHOOTING GUIDE IF DEVICE LATCH IS NOT RETRACTING PROPERLY WHEN POWERED, FOLLOW THESE STEPS I...
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
If mechanism cover plate causes the EL solenoid to drop when slid over the solenoid, the solenoid plunger requires adjustment.  You must lengthen the rod by turning the hex nut in front of the plun...
  Pushing on the push  bar or activating the EL/QEL or the trim on Von Duprin XP98/99 exit device does not retract the latch, it releases the latch only. Door must be pushed or pulled when device o...
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices.