This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the XP...
Here are some of the major differences between the M and MA-Series.  Lever mounting post holes -  Locations have changed on door template.  (12 and 6 o'clock for M lock, MA lock is approx 1 and...
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.
The new Falcon T-Series latch, introduced mid-June 2013, will work with all available T lock strike options.  No changes have been made to the strikes.
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...