falcon double door strike

RELATED FAQS

Question
Answer
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike
The 576A or 576B strikes can be used on wood doors but you should check with door manufacturer if it is a fire-rated door to make sure there are no conflicts.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
The Von Duprin 5100 electric strike is not for fire rated applications.
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...
Lip length refers to the dimension from the centerline of the strike screw holes to the edge of the lip.  See the attached as lip length depends on door handing and thickness, Extended Lip Str...
Thermal Bow is a temporary condition which occurs in metal doors mainly due to the temperature differential from one side of the door to the other. This may occur in exterior doors when direct sun ...
The RU lock can be requested as a retrofit for early Corbin Russwin Unit locks.  Several types of strikes are offered depending on the strike conditions but two are very similar with the e...
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame.
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application.  Check the template to confirm compatibility with specific cylindrical lock model n...
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
If the door hits the frame (or rubs on the rabbet of the head or jamb) the frame is out of square and improperly installed. Door edge rubbing on the rabbet - shimming the hinges may resolve the...
The 571 strike is used on the in-active door leaf of a pair or on the 19-V door leaf when both doors are active per template.
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.