The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors. Additional Information: The Von Duprin 4854/9854 mullion is required when using 25R with 6111 electric...
 For the backset see the Falcon template above, the "B" dimension would be 3-1/4".
There are no optional monitor switches available for the 6300 electric strike.
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...