Falcon M-series strike

RELATED FAQS

Question
Answer
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.
The new Falcon T-Series latch, introduced mid-June 2013, will work with all available T lock strike options.  No changes have been made to the strikes.
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors. Additional Information: The Von Duprin 4854/9854 mullion is required when using 25R with 6111 electric...
 For the backset see the Falcon template above, the "B" dimension would be 3-1/4".