fast track chexit

RELATED FAQS

Question
Answer
The SE series track is the same for all models. It is ordered by the closer model, followed by a -3038.  Example -- 4040SE-3038 (specify voltage & finish) or 3130SE-3038 (specify voltage & finish)...
For devices shipped after 8-24-2015 with motor driven:  a.       0-200 ft, use  #18 gauge wire b.      0-500 ft, use #14 gauge wir...
For Product Shipped prior to 8-24-2015 with solenoid driven:          a.       0-100 ft, use #14 Gauge Wire      b.&n...
For motor driven Chexit devices shipped from the factory after 8-24-2015, the RX switch is standard, part number 116717-00.    
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX-RX switch" by SSC or distributors.  The switch may only be installed o...
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
The micro-switch with two orange wires is probably the Chexit switch assembly for devices shipped prior to 8-24-2015 with solenoid driven, part number 13-065-00. 
CM locks with a magnetic stripe reader can only be set to read one of the three mag tracks at one time. The CM lock with magnetic stripe reader was shipped from the factory with the magnetic stripe...
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
Followings could cause the Chexit device to go into alarm after the rearm time: Chexit devices shipped after 8-24-2015 with motor driven: Module DPS LED is ON DPS switch contact is open: Close t...
Chexit devices shipped prior to 8-24-2015 with solenoid driven: Chexit device has a RX switch with a connector that needs to be connected to the Chexit module otherwise the alarm will sound af...
You can not convert an SE track to a different voltage in the field as the "solenoid " in a 4040SE track is not field replaceable.  The complete track will need to be replaced.
Make sure the proper power supply (PS873 or PS914) and proper gauge and run wire is used for Chexit devices shipped prior to 8-24-2015 with solenoid driven. Related Solution: What wire&n...
You can contact Allegion Customer Service (Sales Support) or Technical Support (Product Support) by phone or by email. To contact by phone: call 877.67...
NOTE: You can also reach your local sales office by dialing 877-671-7011 and selecting option #3 from the main menu. You will be directed to your sales office based on the area code ...
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
To get a dry contact signal from a Chexit device to monitor the alarm, use the blue and brown wires (do not connect the blue to the red)  of the harness connector cable tha...
The EL Wiring Adapter is not needed for a CX device.
Chexit devices shipped after 8-24-2015 with motor driven:If two pin REX connector cable is plugged into the Chexit module and Module REX LED is OFF, the RX switch is defective and needs to be repla...
Chexit devices shipped prior to 8-24-2015 with solenoid driven:If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defective....
The Von Duprin CX 98/99-4 feet Rim devices on single doors with 5/8" stops and the standard 299 roller strike can be field sized to fit a minimum of 40.2" door opening.  This an...
Part numbers listed below: 2030-3071 cylinder assembly includes the closer cylinder and finish plate.  2030-3971 is the cylinder only. 2030-3002 is the finish plate. 2030-3077T is ...
A thumbpiece, knob or lever trim left in the unlock position would be locked when the Chexit is armed and unlock when the Chexit device is disarmed. To keep the outside trim in the lock p...
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...
For Chexit devices with solenoid driven shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX RX Switch".  It may only be installed or adjusted on ex...
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
If Chexit device LED blink once when you turn the unit on, the External inhibit green wire is not by passed or not connected to the access control normally closed contact.  For devices sh...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
You can use the E996L electric trim with Chexit 98/99 series exit device.
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees. ...
For Chexit devices shipped after 8-24-2015 with motor driven connect your normally closed contact from access control system between green and red on the twelve field wire ...
You can not use these options together on the same device per the following reasons: QEL/EL device retracts the latch bolt of the exit device allowing entry. CX (Chexit) device locks the p...
Chexit devices shipped after 8-24-2015 with motor driven: The Chexit device will use a 1 1/4" mortise cylinder with straight cam. Schlage cylinder 20-001-114 recommended. CAUTION: The length of t...
Chexit devices shipped prior to 8-24-2015:The CX device will need a 1 1/4" mortise cylinder with a straight cam per page 2 of the installation instructions. A 996L-M for a 1 3/4...
Chexit devices shipped prior to 8-24-2015 with solenoid driven could cause the Von Duprin CX solenoid to pull and drop and sound the alarm with solid LED or no LED light after the rear...
Fire alarm contact would tie right into the Von Duprin Chexit device not to the PS914 power supply. There is no requirement to install the fire alarm board.
The Von Duprin Chexit device does not have electric latch retraction feature.
The 4040SE is non handed and can be mounted on the push or pull side of the door.
When CX99L-BE is not armed with key cylinder on the device or shunted by card reader, the exterior 996LBE lever trim will release.