Question
Answer
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc). Walls can be either wood stud or steel stud Used only for interior applicat...
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry Walls: N...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening height ...
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height:  Quantity  Nominal Frame Height     2     1'...
Excessive premature frame rusting is caused by improper jobsite installation practices and most likely caused by the following circumstances: Grout: Frames are grouted in place using incorrec...
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
This condition (toed in or toed out jambs) is usually not found until the door is installed. Frames which have toed in or toed out jambs have been installed out of tolerance. It is the resp...
No, an adjustable base anchor is not supplied on frames with existing opening anchors. The anchor design for use in existing masonry walls, is a pierce and dimple in the frame soffit for 3/8"...
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and ...