labeled and non-labeled

RELATED FAQS

Question
Answer
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...
Dutch doors are available as Fire Rated door assemblies and have similar component requirements as a single leaf fire door. Exceptions are as follows: The Dutch Door assembly must have a lock...
A fire rated door for 3 hours can have one glass light maximum: 100 square inches and must have an approved glass (Firelite type) Max glass size cannot exceed 12" in width or 33" in height. Wi...
UL, WH, FM
Conforms to all applicable codes, governing fire rated doors and bears label
ULA or 3 hour or 180 min., ULB or 1 1/2 hour or 90 min, ULC or 3/4 hour or 45 min, ULD, ULE, WH3, WH1 1/2, 20 MINUTE; UL, WH, FM
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height:  Quantity  Nominal Frame Height     2     1'...
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory Default Reset (FDR) to remove any previ...
Manually Setting the RS-485 Address This method is only available before the first network communication between an Access Control Panel (ACP) and the lock. Do a Level 1 and Level 2 Factory De...