EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm do...
The standard 1460 EDA arm is not long enough to allow the door to open 180°.
The 1460 Regular Arm part numbers are: Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish). Regular Arm with PA -- 1460-3077PA (must specify finish). Regular Hold Open Ar...
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.
The 4110 EDA/HEDA can be templated for 100°, 140°, and 180° hold open. The hold open adjustment can be set to hold the door at any position (degree) up to the maximum door opening angle. For "Wi...
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
The Falcon FA arm is a non-handed arm similar to the LCN EDA arm.The Falcon FA-HO arm is a handed arm similar to the LCN HEDA arm.
The 419 panel adaptor is the replacement for both the obsolete 145 shoe, and 418 panel bracket (both were made obsolete in 2009). The 419 panel adaptor is 4" wide, 2" tall, and projects 3". ST-069...
The dead stop post would need to be removed and the 4040/4040XP EDA mounting template for 180° would be followed.