lcn swing clear

RELATED FAQS

Question
Answer
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
Here is an updated list of errors shown on keypad display of the Senior Swing control: Er04 - Voltage Monitor was high during Opening hardware check. Er05 - Master or slave CPU has oscillator ...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
EPT can be used on following hinges: Degree of the opening Hinge type Door thickness 0-180 degree Up to 5" butt hinges 1 3/4" 0-180 degree Up to 3/4" offset pivots 1 3/4" 0-130 degree 5 1/2"...
See related solution: Can an EPT be used with Cam Lift Hinges?
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
No, the geometry of a swing clear hinge prevents the coordinator from working correctly.  The bar style coordinator will not hold the active door open far enough for the inactive door to clear the ...
Push Side Surface Mount Senior Swing can be used with swing clear hinges, standard templating. Pull Side Surface Mount Senior Swing cannot be used, the pull arm will hit the back of door at approxi...
Swing clear hinges are available with TW (through wire).