posts for round actuators

RELATED FAQS

Question
Answer
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. This harness p...
The 4630/4640 operator activation inputs are: Normal Activation Inputs (2 parallel) - terminals 16 & 17 or 18 & 19. Sequential Input - terminals 8 & 19. Alternate Action Input - terminals 15 &...
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator. The first activation would open the door, the second...
The LCN Bollard post (8310-866) only accepts the "square" actuators (no round actuators). The size of the Bollard post is 4” X 6” X 36”. Acceptable actuator part numbers are: Hard Wired -  831...
To convert a hard wired actuator button to a wireless actuator button you will need the following components: An RF transmitter. The 8310-844 transmitter for the (4-1/2" or 6" round, and the ...
To convert an RF actuator button to a hard wired actuator button, simply remove the RF transmitter an connect the hard wiring to the "Common" and "Normally Open" terminals on the the switch.
The 7910-956 actuator direct replacement is the 8310-856 actuator.
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...
To program the 8310-865 receiver: Set the dip switches 1 to the "OFF" (pulse) position. Set the dip switches 2 to the "OFF" (0.5s) position. Momentarily press the " No Delay" or "Delay" ...