Question
Answer
Use #18 gauge wire up to 200 feet maximum distance from PS900 x 900-2Q power supply to the QEL exit device. The new QEL+ no longer requires the 900-2Q board but still needs a different option board...
The 900-2Q board is no longer available. For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board.
No, you can only add one 900-2Q option board to the PS902 power supply and 900-2Q only can support two QEL devices.
The old MPB842 power supply will power up to two EL electric panic bars but will not power the QEL devices.  A defective potted module inside the electric panic bar or defective power supply coul...
Yes the Von Duprin QEL exit device retracts the latch bolt and pushpad. Pushpad and latch bolt stay retracted as long as power is applied to the QEL exit device.
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
The EL wiring adapter is not needed for QEL devices.
Kits are available per the following criteria.    Product Bulletin Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish  Optional LX...
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...