strike dor nd series

RELATED FAQS

Question
Answer
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
As standard the ND lock is not available in a 609 finish.
The ND12 and ND25 are both exit locks.ND12 Outside lever always fixed. Insidelever always unlocked for immediateegress.ND25Blank plate outside. Inside leveralways unlocked for immediate egress.
Latches are sold separately, see current Pricebook for part numbers.
ND locks shipping on or after January 30, 2017 no longer require the use of the soft durometer spacer. Lever installation on the redesigned ND locks should not be difficult.
For ND locks shipping prior to January 30, 2017, the addition of the soft durometer spacer (SDS) on August 15, 2012 did affect the installation of the lever.  Ultimately, removing th...
Schlage offers the 10-042 Electric strike, 1 1/4" x 4 7/8", 606 and 626 finish only. Related solution: What are the current and voltage requirements of the 10-042 strike?
There are two flat lip strike options: Specify XQ02-309 for a 10-013 strike - specify 7/8" Specify XQ07-351 for a 10-025 strike - specify 7/8"
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core