triangles lined up

RELATED FAQS

Question
Answer
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
1) Make sure the lock batteries are more than 4.0 volts. The USB connection will not detect or communicate with a voltage lower than 4 volts. Many times a firmware update will draw d...
2) Make sure the SUS/HHD is set to communicate using USB connection mode in SUS.  You should see the familiar USB symbol on the SUS main Screen in the bottom right corner.  If you see a S...
3) When you update with NEW firmware replacing very OLD firmware a S1 RESET is suggested after the update. This initializes all the AD-Series memory locations to the new firmware. S1 is the ...
4) Make sure the HHD-USB cable is securely inserted into the HHD and into the lockset.  
5) Inspect the HHD-USB connector(s), ensure no pins are damaged, recessed or out of alignment. If a damaged cable is found customers should see their dealer for a replacement or they can order a re...
5) If working with a CO lockset, the mechanical key switch needs to be in its "Inactive" or normal position.  Ensure the triangle alignment on the front escutcheon and that...
Make sure the lock AA batteries are good. 4.8 VDC or higher.
When in its “Active state”, the mechanical key switch can prevent USB connection. Make sure the lock key cylinder and tailpiece are properly installed.
Make sure the mechanical triangles on the back of the outside escutcheon are aligned properly.  See the installation instructions at www.schlage.com/support Schlage Technical Support.&nbs...
If the Schlage Utility Software pops up a "E201 error", just ignore it, and tap "Device Options" or update your firmware. See 78451  
Make sure the HHD/SUS is set to USB communication by checking the small icon right of the "No Device Connected" message.  The symbol should be a USB symbol when working with USB enable product...
Installers have reported that their AD-CO Series cylindrical or mortise locks will unlock whenever the outside lever is lifted.    This will occur if the outside spindle (square post) is install...
With the new FW package 2.19.0; AD300 FW 2.17.0 and AD400 FW 2.17.0 (released 09/23/2011) the firmware looks for a motor clutch switch change after a motor move command. If there is no motor clutch...
If the triangles in the spring cage spindle are not aligned properly the motor will not move enough to change the clutch switch. Is is very likely with a lock on the bench; but a properly install...
When the new firmware moves the motor three times without seeing the clutch switch change it reports to the SUS diagnostics that the motor is stalled. Aligning the triangles will let the motor move...
If the lock is mounted on the door, it is necessary to adjust the mortis/cylinder tightness and spring cage tailpiece alignments, making sure there is no binding or stopping of the spring...
Just align the triangles per the installation instructions to allow full motor movement.   - This will eliminate the SUS motor STALL report. - This will eliminate the three ...