WHAT ANCHOR TYPES ARE OFFERED FOR FT FRAMES

RELATED FAQS

Question
Answer
For both DW and K-Series Drywall Slip-on frames, Steelcraft locates the compression anchor in the jamb soffits approximately 4" down from the head on each jamb. Regardless of door opening height: ...
No, an adjustable base anchor is not supplied on frames with existing opening anchors. The anchor design for use in existing masonry walls, is a pierce and dimple in the frame soffit for 3/8"...
Both the DW and K-Series frames are identical with the exception of the base anchoring. Both the DW and K-series frames are supplied with a field adjustable compression anchor in each jamb located ...
Yes, stainless steel doors and frames are available. Door Construction: LS-Series: Visible edge seams Door construction similar to the L-Series LSW-Series: Seamless with we...
Masonry T anchor are approved for fire rated frames up to 3 hours. T Anchors are shipped lose for field installation. Anchor construction: The T portion and the strap do have minimum dimensions th...
CAD drawings are available for doors and frames in 3 drawing formats: Autocad (.dwg) - Release 12 Encapsulated PostScript (.eps) Data Exchange (.dxf) Drawings are available on the...
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual pages 2.4.1 thru 201.16.Basic guidelines are as follows:Anchor Quantities:• 3 p...
Yes, an additional jamb anchor can be used at the bottom of the frame in lieu of the typical (adjustable or weld-in) base anchor in fire rated frames. This is limited to the anchor designed for...
Cabinet Jamb
F-Series frames are available without returns: Fire Rated frames must have welded corners. Frames must include weled in wood or steel stud anchors. Installation requirements: Frames must be...
Steelcraft does offer Thermal Break Frameson the FT series. Thermal break frames are available as:3-sided frames onlyFrames are available in 16 or 14 gauge steelFT series frames meet the requi...
Additional information on Thermal Break Frames can be found on Tech Data Pages 224 thru 227 
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows:  Frames are supplied knock-down (KD). Fram...
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   The 6211 is used if the frame is being replaced. The 6210 is for ...
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc). Walls can be either wood stud or steel stud Used only for interior applicat...
Some architectural specifications require steel frames to be back-coated with a bituminous coating for corrosion protection or sound control. It is commonly specified to be used in condit...
A Kerfed Frame is a frame that is formed with an optional integral pocket or recess in the area of the stop to receive gasket, seals or weather stripping. Kerfed frames are available as an&n...