The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...
A PBKIT is a Pushbar Retrofit Kit.The pushbar retrofit kits are not the same for 33A/35A and 98/99 series exit devices.  Depending on the finish of the exit device, the pushbar end caps are di...
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate.  If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.
The push bar end cap is only included in the push bar replacement/retrofit kit (PBKIT) because the end caps are riveted to the push bar.   
How to order:  specify devise type, size, and finish.  Example: PBKIT 33A 3' US28