what power supply is needed for maglocks

RELATED FAQS

Question
Answer
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
We no longer offer a delay egress board in the P900 series power supplies.
The delay egress is controlled in the exit device (Von Duprin Chexit), the magnetic lock, or other locking device.
INPUT -- 120 volts AC @ 1 amp. OUTPUT -- 12 volts AC @ 0.25 amp (1/4 amp).
The Falcon 8200 series operator requires a input of 120 VAC @ 1 Amp.
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.
You can power both mag locks and EL devices from PS914 power supply.
It requires 900-4RL and 900-FA option boards to release the mag locks when a fire alarm is activated. Specify PS914 x 900-4RL x 900-FA.
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
This is possible as long as the total current draw does not exceed the 2 amp capacity of the PS902 power supply. The Schlage Electronics 320, 350, or 390 maglock must be used with a DE5101 and th...
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that v...
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...