WHERE CAN I FIND LCN SPECIAL TEMPLATE LIST

RELATED FAQS

Question
Answer
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
The LCN 4010SE / 4110 SE series are obsolete, and on longer available. They were replaced by the 4040SE series. The 4010SE / 4110 SE track is replaced with the current 4040SE trac...
ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
LCN no longer sells, repairs, or has any replacement parts for the track of the old SED units which had a built in detector in the track.    
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
ST-2730 is used with a 4110 closer and GJ90 series (up to size 4).  ST-2730 includes a special template and special arm with a -62G shoe and bent forearm. If a drop plate is required, a 4010-18 d...
You will need to use Special Template ST-3448, allows you to mount the 4041EDA and a GJ81 Series (814-816).
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiring per ST ...
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template.  The 4040 door closer is on the pull side of the door and the GJ 90 is ...
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. 
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...