Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...
The 4600 operator is designed to meet the ANSI Code 156.19 that limits the opening force to a 15 lbs.  By code and design, the operator must stop opening the door when an obstruction or resistance ...
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as assemblies wit...
Hurricane ratings vary by location and application.Be sure to check with the local authority and/or the Regional Allegion Specification Consultants to determine what products are appropriate for yo...
The Von Duprin XP98/99 exit device is hurricane rated for single or pair doors.