add electric strike same backset

RELATED FAQS

Question
Answer
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The backset is the same for the 6300 surface mounted electric strike as it is when using the 299 strike.  There should be 3/16" from the face of the device and the face of the strike.
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...