Question
Answer
The Schlage AL-Series SFIC locks require one (1) small format spacer (D500-000) for 7-pin cores and two (2) small format spacers for 6-pin cores.  When these spacers are not ins...
The new AL FSIC driver part number is A700-052.  This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring.  Th...
The lever may be missing the slot feature for the core locking lug.  Verify slot is in place.
In 2002 the Schlage AL-Series underwent a design change that affected the spring cage, driver, and plastic insert.  Spring cage and driver replacements for AL locks manufactured before this design ...
You can not install the S lever onto an AL lock.  The AL and S lever trim is not compatible with each other.
Changing the plunger assembly on the AL-Series requires disassembling the chassis.  Refer to Plunger Assembly Instructions for guidance.
The AL-Series has four distinguishable parts that can help in lock identification.     1.   The AL-Series will have a castle nut holding the chassis on the ...
The following Legacy information is important to understand before cross referencing power supplies: PS-900 option boards will NOT install onto the legacy power supplies. This includes battery a...
Von Duprin PS914-4RL power supply replaces the PS873-4TD.
According to ANSI specifications for cylindrical or mortise locks: The lock strike centerline should be 40 5/16" from the bottom of the frame with the lock in relation to the strike.&...
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed.  In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.
For compression anchor details refer to the “ANCHORING SYSTEMS”  section in the Steelcraft Tech Data Manual.