Schlage offers a High, Medium, and Low risk HSLR ligature Resistant trim offering for the L9000 and ND locks, Data Sheet.Schlage offers a Low to Medium Risk SL1/SK1 ligature resistant trim for...
High Risk Areas*Patient bedroomIn-suite bathroomIn-suite closetTime-out roomPatient difficult to manage; or risk of solitary and/or unsupervised areas.Medium risk areas*Living roomDining roomGroup ...
The AD200, 250, 300, and 400 trims will work with the Von Duprin 98/9975 mortise Exit Devices.
The part number for the AD or CO twisted tailpiece kit is: 46929303 Tailpiece Kit - (for Exterior Escutcheon -993 into Exit Device, i.e. Von Duprin 98 or 99) Exit Trim 46929303 Includes the...
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
The standard L9000 lock can be ordered for thin doors (1 3/8") and the appropriate parts will be shipped.  The LV9000, L400, LM9000, Anti-Ligature, and N escutcheon trims a...
The Schlage SL1 ligature resistant lever is designed to break-away between 100 and 200 inch-pounds.  The lever will rotate at this point but not allow access.
Torx screws are not standard on the SL1/SK1 trim but are available as an option. Specify the L283-121 Torx screw pack.  This pack includes torx screws for the armor and strike.