can an exit device be hurricane rated

RELATED FAQS

Question
Answer
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
There is not a fire rated version of the Von Duprin 33A/35A rim device.  Only the vertical rod devices (33/3527A-F, 33/3547A-F, 33/3548A-F) can be fire rated.
Installation should be 6" from bottom of the door. See attached templates as reference.  T-5494 for HM Doors W-5494 for Wood Doors
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
AFL stands for "Auxiliary Fire Latch" on fire rated exit devices.
No, dogging cannot be added to a fire-rated mechanical exit device. Fire rated devices can be only electronically dogged and drop during fire activation.
Fire rated devices are not an option.
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. 
9875-F Series,9975-F Series , 5575-F, 8875-F
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
Fire rated exit devices can't be modified to different model per UL requirements.
While they are both mortise locks they are not interchangeable.  You would NOT be able to use a L9000 with a VD panic device. You would NOT be able to use a VD 7500 with Schlage lev...
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...
 HD-EL (Hex Dogging Electric Latch Retraction) solenoid and plunger can be replaced with standard EL solenoid and plunger on non fire rated exit devices, but this should not be used on a daily basi...
LR is the regular/ standard latch and PL is Pullman/ES (Electric Strike) latch for the Von Duprin 8827 exit device.
 ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.
We don't recommend to use the old style hex dogging kit into the new 98/99 exit device but it would fit as long as the device is not fire rated.
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK option on non fi...
Falcon 25 series is a ANSI/BHMA A156.3 Standard for Grade 1 device.
Falcon F-25 series is the UL Rated Fire Exit Hardware device is a ANSI/BHMA A156.3 Standard for Grade 1 device.
A copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site. BHMA
Order the 25 device with the "HH" prefix as described in the device options in the Price Book.
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...
HH hurricane rated devices usually have a deferent strike and fire rated mullion. Standard 98/99 series exit devices can be converted to HH by changing the strike and mullion on pair of doors. ...
The Von Duprin XP98/99 exit device is hurricane rated for single or pair doors.
Hurricane ratings vary by location and application.Be sure to check with the local authority and/or the Regional Allegion Specification Consultants to determine what products are appropriate for yo...
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as assemblies wit...
A standard exit device can't be modified to a fire rated exit device.  A new device must be purchased.
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series Doors...