can automatic door opener work with and card reader strike

RELATED FAQS

Question
Answer
The 9550 series Senior Swing WILL NOT work on a pair of doors with Electric Strike and auto flush bolts because you cannot sequence the door openings with a 9550 simultaneous pair operator.&...
All Schlage/XceedID wiegand proximity readers currently understand: -ASK (Amplitude Shift Key) - Used in GE/CASI -FSK (Frequency Shift Key) - Used in HID Prox, AWID, and Lenel The third proximit...
ISOX card technology is no longer supported - contact XceedID sales
When a CX99L-BE is not armed the exterior 996L BE lever trim will be free to retract the CX latch for entrance.  When the CX99-L BE is armed the exterior 996L BE lever will not move and...
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...