can you have CD and QEL on same device?

RELATED FAQS

Question
Answer
A non-fire rated QEL, QEL+, and QELA exit device can be converted to HD by removing the motor and adding the Hex Dogging Replacement kit 050709, and the HD conversion kit, 050114 for 33...
There is not enough room for both options as the dogging mechanism in a standard cylinder dogging and the electronics for the EL or QEL options are both located at the end of the base plate. For 9...
You can not use these options together on the same device per the following reasons: QEL/EL device retracts the latch bolt of the exit device allowing entry. CX (Chexit) device ...
As of 1/15/2012 the 94/95 device is available with a QEL electric latch retraction option. See attached bulletin.
The cam is not inverted on the mortise cylinder for the CD option.
Cylinder dogging (CD) and an RX switch can be ordered together with 33/35 or 98/99 series.
This can be done ONLY with non fire rated exit devices.
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
Cylinder dogging CD is not available with 22 series exit device.
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK opti...