can you use nl-op with mortise panic

RELATED FAQS

Question
Answer
For night latch function with pull by others, the 98/99 series mortise exit device should be ordered as NL less trim, e.g., 9875NL-L/TRIM.  We will furnish a device only, and the mortise cyl...
A 1-1/8 through 1-1/2" mortise cylinder with straight cam per Step 4 of 512NL Instructions.
The Falcon Monarch 510L and 510L-NL trim will accept either a 1 1/4" Mortise cylinder with a straight cam or a 1 3/8" Mortise cylinder with a straight cam using the blocking ring provided with the ...
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as se...
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
This is possible: For metal doors prep door according to the 24R/V NL-OP Template or the 25R/V NL-OP Template and for wood doors use 24R/V NL-OP Wood Template or 25R/V...
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices. The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.