For most exit devices, please refer to the specific device series catalog for minimum door opening width the device can be cut down to fit.
Be aware that some device options, frame...
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
The 900-2RS is recommended to be used with EL devices but if you have a 900-2Q with PS914 power supply it can be used to operate up to two EL or one EL and one QEL devices .
You can not use these options together on the same device per the following reasons:
QEL/EL device retracts the latch bolt of the exit device allowing entry.
CX (Chexit) device ...
The Von Duprin EL33A/35A/98/99 device can be converted to the QEL device by getting the correct sized QEL baseplate conversion kit. The existing PS914 or PS873 power supply can be used.
...
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003). At one time, the obsolete black EL ...
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
There is not enough room for both options as the dogging mechanism in a standard cylinder dogging and the electronics for the EL or QEL options are both located at the end of the base plate.
For 9...
The 900-2Q board is no longer available.
For warranty purposes, QEL conversion kit and 900-2RS board are required. The 900-2RS replaces the 900-2Q board.
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...
Yes the Von Duprin QEL exit device retracts the latch bolt and pushpad.
Pushpad and latch bolt stay retracted as long as power is applied to the QEL exit device.
The old MPB842 power supply will power up to two EL electric panic bars but will not power the QEL devices.
A defective potted module inside the electric panic bar or defective power supply coul...
The QEL exit devices that were shipped prior to August, 2012 will only communicate to the PS873 with 871-2Q option board or PS900 series with 900-2Q option board.
If you...
Calibration is an internal process of the QEL device when energized the 1st time. The solenoid will pull and drop 3 times on a standard calibration. Calibration can be forced by pr...
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...
The following could cause the QEL device to retract and release repeatedly:
If this is a vertical rod type device, the vertical rods could be adjusted too short.
Check rods for dead locking, ...
Pushing on the push bar or activating the EL/QEL or the trim on Von Duprin XP98/99 exit device does not retract the latch, it releases the latch only. Door must be pushed or pulled when device o...
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011.
The device can be ordered standard with cylinder dogging and exit alarm ALK opti...
See below for QEL device requirements: QEL devices shipped prior to 7/23/12 must have the 2Q option board for the communication link between the power supply and the exit device. &nb...