On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND. You will need to contact Medeco for the cylinder Specify a key-in-lever cylinder to fit the Schlage ND lo...
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...
ND -series locks manufactured on or after January 30, 2017 use the following spring cages:Outside - N523-218 - For ALL cylinder options except for JD-YA6, JD-YA7 and JD-MEDInside - N523-222 -...
ND-series locks manufactured before January 30, 2017 used the following spring cages:
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs available vary d...
The Schlage ND is shipped with a driver/tailpiece when ordered with a LD, BD, or JD suffix.
The ND electrified motor driven locks shipping as of  March 14, 2016 has a field selectable operating mode, you can convert from EL to EU or EU to EL by flipping a switch on the chas...
The electrified ND electrified solenoid driven lock shipped prior to March 14, 2016 can be converted between fail safe (EL) and fail secure (EU) by swapping out the solenoid, sleeve,...
On ND-series locks manufactured on or after January 30, 2017, the following parts are needed to convert the lock from JD to LD:03-231 - Open Cylinder lever (specify design and finish)N523-022 - Tai...