chexit conversion kit

RELATED FAQS

Question
Answer
There is no conversion kit for Von Duprin Chexit device.  If delayed egress Chexit device is required, the entire device must be replaced.
For motor driven Chexit devices shipped from the factory after 8-24-2015, the RX switch is replaceable as part number 116717-00. Note:  A slight change to the plastic housing was ad...
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is no longer available.  This part was discontinued in 2019. If the older version Chexit RX s...
If the horn fail to operate in the CX device you need to replace the Chexit module. 040086 is the part number for devices shipped after 8-24-2015 with motor driven.050228 is the...
The circuit board is sometimes referred to as a "module" in the field.
The Chexit device has a different base plate and center case than the ALK.  The Chexit device would need to be replaced with an ALK device.
The release delay time for the Chexit is programmed into the Chexit module and cannot be changed in the field. The ability to change the delay time is restricted by the UL listing of the devi...