EDA ARM - The EDA arm is a heavy duty parallel arm mount. The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
The (SF) "Swing Free" arm allows the door to be put into hold open position, but then repositioned (swing free) to any other degree of opening without taking the closer out of the hold open mode....
2030 and 5030 are both overhead concealed closers. Catalog information can be found here.
The 2030 uses a concealed, in the door, track, and a concealed one piece arm.
The 5030 use...
The correct method (process) for setting the hold open is:
The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm)
Loosen the hold open nut.
Opened the door ...
This can only be done with universal, non-handed closers: 1250, 1260, 1450, 1460, 4030, 4040XP, and 4050A.You would need an xxxx-62PA shoe to adapt from regular arm to parallel arm mount...
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door.
Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...
The 1460 Regular Arm part numbers are:
Regular Arm -- 1460-3077 or 1460-3077L for long arm (must specify finish).
Regular Arm with PA -- 1460-3077PA (must specify finish).
Regular Hold Open Ar...
The 2010 and 2030 closer are not the same.
The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in.
The 2030 uses the (narrow) "Pacer" cylinder...
The 1260 closer body has the same footprint (9-1/16" x 3/4") and it mounts in the same location as the 1070 body, but the arm will have to be moved slightly to match the 1260 templating.
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed.
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...