closer in header

RELATED FAQS

Question
Answer
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors.  Both units contained within the same Senior Swing header. To order a paired operator with a 2810 on&nb...
Steelcraft offers two optional types of reinforcements for open section header to be installed in distributor shop or in the field: Full profile sleeve; is a 14 gauge, 16" long part to fit the p...
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
How to Order: The Senior Swing header is ordered by the width of the door(s). The measurement from inside jamb to inside jamb of the frame. If the Senior Swing header is ordered the wrong length, ...
Senior Swing Power Operators
Head, Swing operator housing
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.
All the 2030 series closer have a fixed spring sizes. Example -- a 2031 has a size 1 spring,  a 2302 has a size 2 spring, 2033/2034/2035 etc. All the 2030 series closer are shipped at the weakest s...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...
The EDA (Extra Duty Arm) is the standard arm for the 4110.
The measurements from center line to centerline of the mounting holes are 2-3/8"  x  6-3/4".
A  LHR (left hand reverse) door uses a RH (right hand) door closer. A RHR (right hand reverse) door uses a LH (left hand) door closer.
A door can be handed in several ways. The easiest way is to stand on the Push side of the door. Push the door away from you as if you are going to walk thru the opening. If the hinges are on yo...
To determine the hand of a door, view the door from the outside, security side or key side of door.  Once there identify which side are the hinges located on the, right or left side of t...
Go to the push side of the door opening.  See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...
The current Powder Coat finishes are: Aluminum (BHMA 689) Dark Bronze (BHMA 695) Brass (BHMA 696) Light Bronze (BHMA 691) Statuary Bronze (BHMA 690) Black (BHMA 693)For list of standar...
Tan Powder Coat can be ordered but only available as a special finish with a metal cover.
White Powder Coat can be ordered as a special RAL finish with a metal cover.
For custom powder coat (LCN RAL customer powder coat colors) guide/chart please see here.
24 volt version draws 90 mAmps (0.090A). 120 volt version draws 30 mAmps (0.030A).
As of today the 1460 is the closer "series number", and 1461 is the closer "model or ordering # ". Both numbers represent the same door closer, there is no difference.
The LCN closers are not designed nor intended to be exterior mounted in the elements.
The 2210 DPS "switch" and "plastic (setting) gear" ARE NOT sold or replaced separately.  The closer has to be replaced or sent back to LCN for repairs to have a new switch or plastic (setting) gea...
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. 
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer.  If required, handing can be verified by looking at ...
Product shipped on or after Feb. 8th, 2016 The "3034" and "3034H" are internal part designation that LCN uses to specify regular (3034) and hold open (3034H) roll...
On Feb 8th, 2016 - LCN launched the redesign of the Hold open clip which changed multiple components of our Track style closers, including the roller, track, hold open clip, and bumper. 
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.
The 1260 closer body has the same footprint (9-1/16" x 3/4") and it mounts in the same location as the 1070 body, but the arm will have to be moved slightly to match the 1260 templating.
 The P1070 was replaced with the 1261 Rw/PA.
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
This condition can be caused by the "closing speed adjustment" being regulated for a fast closing speed. Try adjusting the closing speed to slow down the closing of the door. If that does not corre...
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
4040-71 is the casting number on the 4041/4040XP door closer cylinder body.
The date is a 4 digit #. The first 2 numbers indicate the week it was made, and the last 2 numbers indicate what year it was made. On most surface mounted closers, the model #,  date code, ...
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
120V Models: The hold open force on the 2310ME / 4310ME / 4410ME closers is "NOT" adjustable. 24V Models: There is a trimpot adjustment on the circuit board that allows you to "REDUCE" the hold op...
The Dor-O-Matic overhead concealed manual door closers have been obsolete since 1999, and there are no parts available for them.
The 4041/4040XP and 4040SE closers cylinders are "NOT" the same. The 4041/4040XP cylinder has an adjustable size 1-6 spring. The 4040SE cylinder has an adjustable size 2-4 spring. The 4041/404...
The Rw/PA arm is simply a regular arm that is packed with a 62PA (parallel arm) shoe, which will allow a (Tri-Pack) closer to be mounted in a regular, top jamb, or parallel arm application.
4810 series is a Top Jamb Pull Side application. 4820 series is a Top Jamb Push Side application. 4840 series is a Parallel Arm Push Side application.
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.
The LCN closer fluid "Liquid X" will perform without variation between:  -30° F to +120° F - for manual closers.  +35° F to +120° F - for electrical closers and automatic operators. At around ...
When templated for 140° the 4010 will fit on a 16-1/2" door leaf MINIMUM.
The (SF) "Swing Free" arm allows the door to be put into hold open position, but then repositioned (swing free) to any other degree of opening without taking the closer out of the hold open mode. ...
14" door leaf is the narrowest with standard template.
The 4040SE is non handed and can be mounted on the push or pull side of the door.
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...
Finish is not specifically stated as being covered under warranty as it is covered under defects in material and workmanship.  EXCEPTION: There is no finish warranty for Falcon products. ...
Falcon lock warranty statementIves warranty statementGlynn-Johnson warranty statementLCN closer warranty statementSchlage warranty statementSteelcraft warranty statementVon Duprin warranty statement
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.
Allegion order forms are only available to Authorized Distributor Partners.  Authorized Allegion Distributor Partners can view order forms and ordering information by logging onto the “My All...
 The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...
AutoCAD drawings are proprietary and are not available for distribution.    
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...
The comparisons of these products are shown below. The 4010T, 4020T, and 4110T cylinders have a longer pinion shaft than the 4010, 4020, and 4110 cylinders. The 4010T,4020T, and 4110T all use t...
The 4040XP/4041 Cush and HCush (Hold Open Cush) use the same instructions / template.
The part number is: 1461-3071 for the door closer cylinder body.
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware...
Locate closer and arm from the centerline of the swing clear hinge pin.
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. 
The Falcon SC60, SC70, and SC80 series closers all use the same arm options. The SC91 series uses a different arm from the rest.
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...
The 4010 and 4020 use the same door closer cylinder, the rod and shoe and covers are different. To use a 4010 cylinder as a 4020, you will need a 4020-79 rod and shoe and a 4020-72 cover. To us...
A 1460 Pull Side can be mounted standard template for 180°, frame and trim permitting.
A 4030 Pull Side can be mounted standard template for 180°, frame and trim permitting. 
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.
The 4011 can only mount on the Pull Side of the door and the 4111 can only mount on the Push Side of the door. Differences - The 4011 and the 4111 cylinders are different and the pinion shafts are...
BHMA provides a certified products directory complete with function codes and meanings from most of the major lock manufacturers.  The most up-to-date directory can be accessed through th...
A designer series metal cover is an option with the 1460 series closer, the part number is, 1460-72DS1.
The maximum 925 tubing run length from the Control Box to the Door Closer is:  7980 Series Control Boxes --- 50 "Linear" feet from Control Box to Door Closer.  7900/7940 Series Control Boxes --...
The SRT screw that is used for mounting the 1461 closer body is 1 3/8" long.Four screws are used to mount the closer body.