Use the cylinder suffix 'T' for full size interchangeable core or the cylinder suffix 'HD' for small format interchangeable core, see Figure 1.  Small format also has a disposable core option ...
A lock specified by a cylinder suffix BDC will be supplied with a disposable small format construction core, see Figure 1 below.  There is no metal key but instead the BDC cylinder has a ...
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.
This only applies to the full size interchangeable cores.  The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed).  Simply add (-ICX) to the end o...
The B250 product line is not available in the SFIC platform.
Specify the J cylinder suffix followed by IC-CR6 or IC-CR7 (6 or 7 pin Corbin core) Example: T581J IC-CR6  This will accommodate an 8000 or 8000-7 Corbin Russwin Full Size core.
Refer to Table 1 for a list of T lock tailpieces for conventional cylinders.  Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock. Example: RU581J IC-SC
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece) Example: T581J IC-SC
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners)     U-Factor = 0.50     R-Value = 2.01B16 Series (Steel Sti...
Insulated Core Options: Steelcraft L-Series doors are available with the following 2 optional insulated cores: Polystyrene slab - this core is available in non fire rated and fire rated doors...
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...
ALWAYS put the PIM400 in LINK mode first. On a PIM400-TD2 press the LINK1 Button for door one, and LINK2 button for door 2. With a PIM400-485 you must use the SUS/HHD to select which door to...
1. To put the AD400 in LINK mode, hold down the RTE (Lever or crash bar see below) and press the # key on the key board, or present a card to the reader.       ...
2. AD400 requires a Request To Exit (RTX) signal to link - see the user guide instructions for the linking process.    For an AD400 to enter link mode, it must see the RTX...
   3. Check the AA battery level, if the AA batteries are below 4.7 volts the AD400 can fail to LINK.             Ins...
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...
ND locks can be extended up to 6" Extended Outside.