control battery holder

RELATED FAQS

Question
Answer
No, the replacement battery holders for Schlage BE467 and FE410 locks do not include the thru-door ribbon cable.   
The original 4B battery holder used with the AD and CO Series products is updated to improve performance.  The issues addressed include: -       Improved spring ...
The original 4B battery holder used with the AD and CO Series products is updated to improve performance.  The issues addressed include: -    New ledges are added near eac...
The Von Duprin PS914-2RS retracts the EL or QEL device approximately 200 times with five second hold time after each pull.
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
Check that the reader is fully seated into the front escutcheon.
Check that there are no bent pins in the reader connector.
Check that the through door ribbon cable is properly plugged in.
Check that the battery or wired power is properly connected.
Check that the batteries are inserted into the battery holder in the correct polarity orientation.
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
First of all, measure the voltage of the coin battery, while still installed in its white plastic holder on the main board ( to find its location, please see lithium battery installation guide )&nb...