CX RX orange wires

RELATED FAQS

Question
Answer
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The micro-switch with two orange wires is probably the Chexit switch assembly for devices shipped prior to 8-24-2015 with solenoid driven, part number 13-065-00. 
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
For the older 17/18 or current 19 device per instructions :  Red - Normally Open  Green - Common   Black - Normally Closed
For 24/25 devices per instructions :   Violet - Normally Open   Black - Common   Gray - Normally Closed
RX wiring on all L9000 locks with RX switch manufactured after January 2, 2017:The L-Series switched to a handed modular three-wire request to exit (RX) switch. This change was originally completed...
Specific to the RX switch installed into the L9080EL/EU and L9082EL/EU and L9000 mechanical locks prior to January 2, 2017:ALL PART NUMBERS BELOW DISCONTINUEDThe L-Series switched to a three-wire r...
The part number for "CX Wiring Assembly" also called "Ten Wire Connector" is 112018-00.  
For Chexit devices shipped after 8-24-2015 with motor driven connect your normally closed contact from access control system between green and red on the twelve field wire ...
Chexit devices shipped after 8-24-2015 with motor driven:Attached is the installation instructions of the the Von Duprin Chexit devices that includes the wiring diagrams.Installation Instructions&n...
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...
Chexit devices shipped prior to 8-24-2015 with solenoid driven: A normally closed card reader contact, key pad contact or any other control contact connects to the Green an...