CX RX switch

RELATED FAQS

Question
Answer
For motor driven Chexit devices shipped from the factory after 8-24-2015, the RX switch is replaceable as part number 116717-00. Note:  A slight change to the plastic housing was ad...
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is no longer available.  This part was discontinued in 2019. If the older version Chexit RX s...
Chexit devices shipped after 8-24-2015 with motor driven:   If the RX is plugged in properly and the wires are not damaged it can be tested by pushing in the push pad. When th...
Chexit devices shipped prior to 8-24-2015 with solenoid driven: If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defect...
For Chexit devices with solenoid driven shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX RX Switch".  It may only be installed or adjusted ...
The hole should be drilled in the field once the end cap is located on the door.  It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
The CX device has an internal RX switch that is wired to the CX circuit board.  This RX switch is not available to outside monitoring and no other RX switches may be added to the CX device.