The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.
The Von Duprin PS914 power supply must be used on the EL devices with either the 900-2RS or 900-4RL option board since the EL devices requires power supplies set at 24VDC to be able to provide the ...
  You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board  will power 1 or 2 devices that do not require timing from pow...
If your Von Duprin EL (solenoid) device pulls and releases quickly instead of holding the latch retracted, please check all of the items below.In most cases, one or more of these solutions will r...
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device.  Maximum allowed force to retract the Von D...
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike
You cannot lock the push side of the exit device as a panic device by design must allow exit.  Any attempt to block an exit is forbidden by code.
No, the 33A is not compatible with the AD and  CO 993  chassis units. The  33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired, you would need the Fire or Less Dogging Cover Plate for EL/QEL conversion kit and Panic cove...
All the templates can be found at us.allegion.com   Please click here