Doors keep getting updates

RELATED FAQS

Question
Answer
Update your lockset using ADFwPkg 2.19.0 or higher.  This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
The NoTour function only allows writing to 11 sectors on the fob.  Each lock added to a user uses 1 sector.  Once those 11 sectors are full, No Tour is not available.  You can ...
The E201 message can be ignored and all normal SUS and lock functions will be maintained.  Click "OK " and continue. Update the Schlage Utility Software (SUS) to version 4.6.0 or highe...
With the new FW package 2.19.0; AD300 FW 2.17.0 and AD400 FW 2.17.0 (released 09/23/2011) the firmware looks for a motor clutch switch change after a motor move command. If there is no motor clutch...
If the triangles in the spring cage spindle are not aligned properly the motor will not move enough to change the clutch switch. Is is very likely with a lock on the bench; but a properly install...
When the new firmware moves the motor three times without seeing the clutch switch change it reports to the SUS diagnostics that the motor is stalled. Aligning the triangles will let the motor move...
If the lock is mounted on the door, it is necessary to adjust the mortis/cylinder tightness and spring cage tailpiece alignments, making sure there is no binding or stopping of the spring...
Just align the triangles per the installation instructions to allow full motor movement.   - This will eliminate the SUS motor STALL report. - This will eliminate the three ...
PIM400-485 and AD400 Two red SCHLAGE LED flashes indicates the AD400, PIM400-485 and ACP all have operational communication, and the ACP denied access with a RS-485 command. With a PIM400-485 tw...
PIM400-TD2 and AD400 Two red flashes indicates the AD400, PIM400-TD2 has radio RF communication; but the AD400 did not get a strike, GO, relay closure from the ACP. With a PIM400-TD2 TWO red fla...
  ONE red flash, One red flash indicates RF COM loss, the AD400 radio did not get an answer from the PIM400-485 radio or the PIM400-TD2 radio. The PIM400-485 will turn off it's radio if th...
With the SUS connected to the AD400, in the EDIT tab there are radio communication settings "FIRST/DELAY/RETRY." FIRST - Is the first delay after the initial transmission of credential data, befor...
AD400 factory default settings when shipped are FIRST = 300 (m sec), DELAY = 200 (m sec) and RETRY = 5  
To change FIRST/DELAY/RETRY connect and couple the SUS/HHD to the AD400 and find under the EDIT tab the FIRST/DELAY/RETRY settings. See notes Or connect the SUS/HHD t...
Some Access Control Panels are designed with “Supervised” or “Dry contact” requirements for the inputs and have no common ground between the ACP (Access Control Panel) and device at the door. “S...
Schlage offers the “RLBD” to support these supervised or dry contact interface applications. The "RLBD" plugs directly into the PIM400-TD2 or PIB300-TD2 for easy hook-up.  
Please reference this Tehnical Note RLBD SES-20120418 for RLBD setup, use information, hook-up diagrams and some testing suggestions when connecting to a Supervised dry contact Access Contro...
This is a link to the RLBD Installation Instructions.
This RLBD data sheet can also be found at Schlage/Technical Support. RLBD DataSheet
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
 8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...