DOUBLE DOOR RIM DEVICE WITH STRIKE NO MULLION
”
RELATED FAQS
Question
Answer
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template
What strike do I use with a pair of 22 rim device without a mullion?
Resolution:
The 1609 strike can be used on an inactive door with 22 rim device. NON-FIRE RATED doors only.
What is the minimum door width for a 98/99 Rim device with 4954 mullion?
Resolution:
Minimum door opening for a 98/99 rim device with a 4954 mullion and 299 strike is 26.687" (26 11/16")
Why does the auto operator not open the door when installed with a Chexit?
Resolution:
Chexit devices are NOT electric latch retraction. In order for Chexit device to operate with an auto operator you will need to add a rim electric strike on a single door or a pair o...
Which strike do you use with an XP98/99 device?
Resolution:
The 909 strike is used in single and paired non-fire rated and single fire rated openings. The 954 strike is used in fire rated paired openings.
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.