Double egress reveal max

RELATED FAQS

Question
Answer
Fire Rated three (3) frames are available in the following maximum door opening sizes: F and FN-Series frame: 4' 0" X 10' 0" single door opening 8' 0" X 10' 0” double door opening MU-Ser...
Reveal should not exceed: 6" for the REGULAR ARM 9 3/4" for the LONG ARM
An LCN 4040T with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE)arm. ST3073 Standard 4040T DE Arm will accommodate reveals up to 2-11/16"....
Maximum reveal for a 4041 regular arm is 2-9/16". The reveal for a 4041 long arm is from 2-9/16" to 4-13/16". The reveal for a 4041 extra long arm (ELR) is from 4-13/16" to 8". ST-2523 is a sp...
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
Max. reveal for a 4642: 4640 Regular arm -- 4.5" 4640 Long arm -- 8" 4640 x ST-3088 ( custom made - extra long rod) -- 8" to 11" No special mounting instructions required, just standard templ...
The maximum reveal for an 8200 Falcon Operator is: 8230 (pull side) -- 1/8" 8240 (push side) -- 6"  The Benchmark long rod and shoe (9140-79LR) can be use with the Falcon 8242 for reveal from ...
No. Fire rated double egress frames must be a stand alone 3 sided frame assembly. If transom lights and/or sidelights are required, they must be built and installed as separate Fire Window assemb...