DW series header drawing

RELATED FAQS

Question
Answer
Dynamic Channel Switching is a feature of the Schlage AD-series wireless access point modules. Dynamic Channel Switching (DCS) increases the robustness of the wireless RF communication in a noisy r...
  Here is a Technical Note on what Dynamic Channel Switching is, what it improves, how to set-up, and frequently asked DCS questions. DCS Tech Note here  
Setting Dynamic Channel Switching   1)     Connect and couple the SUS to the PIM400 you intend to change. See the SUS User Guide for details   2)     Under “PIM Properties” and the “Edit” tab is ...
Security anchors are used in DW/K frames located directly above or below strike preparation on door side of frame. Because there are only two points of anchoring, the compression anchor near the he...
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and ...
This condition (toed in or toed out jambs) is usually not found until the door is installed. Frames which have toed in or toed out jambs have been installed out of tolerance. It is the resp...
Out of plumb (also referred to as twisted) frames usually cannot be adjusted. "Out of Plumb or Twisted frames (or jambs)" is a condition created by improper wall construction and/or improper insta...
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry Walls: N...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening height ...
DW and K-Series frames are designed to slip onto a stud wall after the wall is finished (painted, wall papered, etc). Walls can be either wood stud or steel stud Used only for interior applicat...
It is the responsibility of the installing contractor to install all material in accordance with SDI or HMMA installation standards and tolerances. Out of square frames which are installed out of t...
Both the DW and K-Series frames are identical with the exception of the base anchoring. Both the DW and K-series frames are supplied with a field adjustable compression anchor in each jamb located ...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documentsClick here to get the updated link to the Steelcraft Shop M...