"5, 10 and equal" Hinge Spacing: The industry terminology which usually refers to the Custom (NAAMM/HMMA) Door hinge locations. This location dictates:
Top Hinge - located 5" from the underside ...
Cutout depends on the size of 224 hinge. See 112HD/224HD-EPT template.
112HD/224HD continuous hinge
Center line of EPT to top of the door
83 inches
30 inches
85 inches
32 inc...
Fire labels (UL, ITS/WHI or FM) are located as follows:
Butt Hinges and Pivots:
On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation.
On the fram...
From head to centerline of each hinge (4 1/2" or 5") is 9 3/4", 39 3/64", 68 11/32" & 97 41/64".
The hinge spacing on a 9'0" frame opening height is 29 19/64".
From Head to top of each 4 1/2" hinge is 7 1/2", 36 51/64", 66 3/32" & 95 25/64".
From Head to top of each 5" hinge is 7 1/4", 36 35/64", 65 27/32" & 95 9/64".
The 600/700 Series EPT Template shows recommended locations based on the standard sizes,
The customer can provide a different dimension measured from the top of the hinge to the Cen...
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing
1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges)
from under head CL 9 3/4" (top of door 9 5/8")
from bottom of frame ...
Hinge Backset:
On the frame = 5/16"
On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type).
1. Opening ...
The location to the top of hinge will vary depending on hinge size used.
6'8" Frame with 1 1/2 pair of hinges (top to top):
For 4 1/2" hinges from the head to top of each hinge is 7 1/2", 37 7...
The minimum top and bottom butt hinge locations are as follows:
To the hinge centerline:
4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...
Using Soss hinges with closers can require special device and preparation locations. If you have questions on specific closer applications, please e-mail your request (including a description ...
EPT installation guidelines are as follows:
Recommended location is 6" below top hinge per template
Steelcraft will locate the power transfer prep at the Von Duprin re...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames.
Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
A raceway in a door provides a clear wiring access through the door core from hinge to lock edge.
In a steel (hollow metal) door, the raceway is typically a length of conduit installed during d...
Since most wire transfer devices such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire size for the device....
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes.
Electric Hinges:
Most electric hinges will fit into...
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors
Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached
https://us.allegion.co...
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.
The Schlage ES-6400 Electric Strike has been rebranded to Von Duprin 6400 Series Electric Strike, making Allegion’s full electric strike portfolio Von Duprin branded. All product featu...
Information available at: http://us.allegion.com/products/system_components/electric_strikes/pages/mortise_cylindrical.aspx
Overview, Features and Benefits, Technical Specifications, Wi...
The design change went into effect on 6-16-2011. The stop is now removable and can be changed from one side of the shoe to the other, which makes it a non-handed arm. All arms are shipped standar...
This engineering change did affect the templating of the closer. The stop in the shoe is slightly larger than the original handed cush shoe. The new non-handed arm template locates the closer and s...
Security anchors are used in DW/K frames located directly above or below strike preparation on door side of frame. Because there are only two points of anchoring, the compression anchor near the ...
The 4110 EDA/HEDA can be templated for 100°, 140°, and 180° hold open. The hold open adjustment can be set to hold the door at any position (degree) up to the maximum door opening angle.
For "Wi...
For Steelcraft frame anchor locations refer to the frame "Anchoring Systems" section of Steelcraft's Tech Data Manual.
Basic guidelines are as follows:
Anchor ...
The following are needed for a basic installation:
Fire alarm contact is always required with Von Duprin Chexit device.
1 1/4" Mortise cylinder with straight cam is required&nbs...
The wires in the EPT are larger than the wires in an electric hinge and are less prone to breaking. This is why we recommend the Von Duprin EPT10 with CX device but if necessary yo...