electric strike with vertical rod

RELATED FAQS

Question
Answer
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
No, per the UL Compliance group, the concealed rod devices are only tested with the 338 strike with metal frames. This applies to panic and fire applications.  The 283 strike may only be used ...
Yes, the Von Duprin model 260U strike is intended for surface vertical rod devices with flush transom applications.  There is also a fire rated model called the 260U-F.
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device.  Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish)  Bottom Latc...