This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
Both adaptors are used on the B250 Series for doors prepped with a 2-1/8" bored hole instead of the 1-1/2" bored hole.
38-031 is a light gauge ring for use under a cylinder, diameter is 2 1/2"
...
Schlage H-Series Escutcheons
Part Number
Description
Dimension
07-057
Inside escutcheon and turn
6.92" x 2.75"
07-035
Inside escutcheon, dummy - H170
6.92" x 2...
Outside Knob/Lever and Rose/Escutcheon Assemblies
Part Number
Description
A Rose with Knob/Lever
09-506
Designs: 01 02 03 05 06 07 12 17 18 OME 41 42
09-655
Des...
Coin turn will need to be on a separate line item, specify 09-487 x length (118, 114, 138).This cylinder coin turn is non-handed so it can rotate freely in both directions.
The following list of cylinders were not affected by the change to modular cylinder:
09-900, 09-904, 09-905, 09-907 mortise cylinder turnsSmall format interchangeab...
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.